Conventional Fire Alarm Control Panel 8 Zone
The Conventional Fire Alarm Control Panel 8 Zone is housed in the most attractive, modern designed, friendly user interface for easy operation and recognition. It has smaller size and easier for installation.
Or call +212 5 22 71 84 29
3 documents to download AW-CFP2166-8, ASENWARE CE…Description
Conventional Fire Alarm Control Panel 4 Zone is the central part of conventional fire alarm system, designed for applications requiring smoke detector, bell, manual pull stations, and sprinkler supervision. Each zone can be disabled by a button. The basic unit offers 1 to 8 zones of initiation, up to 32 zones for larger applications.
Conventional Fire Alarm Control Panel 4 Zone Specification:
- It is modularized design, the panel can expend from 1 zone to 32 zones easily.
- 2 level control mode by a lock
- 24VDC and 5VDC power supply output.
- FIRE and FAULT signal output.
- 2 general sounders output.
- Each zone has 1 circuit detectors input
- Each zone can be disable by a button.
- RESET button to reset the panel.
- SILENCE button to stop BUZZER and SOUNDERS.
- EVACUATE button to start a manual fire alarm immediately.
- battery low protection function, when battery voltage lower than 21VDC
- battery will be cut off automatically until the mains power is on.
- an optional GSM module for fire alarm by SMS
The Conventional Fire Alarm Control Panel 8 Zone is housed in the most attractive, modern designed, friendly user interface for easy operation and recognition. It has smaller size and easier for installation.The panel can also be ordered with a metal box.
Conventional Fire Alarm Control Panel 8 Zone
- Automatic power switchover
- 12V2.3Ah High-capacity batteries
- Fault supervision and notification
- 2 relay output circuits
- 2 sounder output circuits
- Sounders and panel buzzer silence
- Extensible application for GSM
- Meets all requirements of latest EN54 part 2 and EN54 part 4
ITEM 8 Zone Fire alarm control Panel Model No. AW-CFP2166-04-16 Mains supply voltage 110VAC or 240VAC Internal power supply 27.2VDC Total output current limited 3A @ 240VAC Batteries (Default Configuration) 12V2AH*2-24VDC in Total End of Line device 6.8k Q,5% tolerance, 0.25W (color code-blue, grey, red, gold) End of line resistor value 6.8k 22,5% tolerance, 0.25W (color code-blue, grey, red, gold) Dimensions(mm) 395*502"124mm Weight (without batteries) 7kg Weight (with batteries) 9.6kg Environmental Class A temperature range: -5 to 50°C
Humidity: 5 to 95% RH, non-condensing
Documents
Documents are reserved for customer accounts. Create a free account
Quote request
Tell us the products, quantities and installation city, and we will reply with a quote.